Fit region: after the peak, C − baseline ≥ max(3, 5% of rise), raw CF1 < 1000 µg/m³ (the PMS5003's credible ceiling). Excluded points are hollow. Run the mixing fan during tests; fit only after mixing (protocol: 10 min for Test A/B). Default baseline is the pre-peak minimum, so start the window a few minutes before lighting the incense to capture the pre-injection level. A baseline set too high inflates k.
CADR = (k_on − k_off) × V. Volume converter: × × ft = – m³. Measure the room properly - a 10% volume error is a 10% CADR error.
λ = R × (k_off + k_purifier) · deposition = k_off − λ · predicted indoor = outdoor × λ / (k_off + k_purifier-in-future-state).